19

Table 6 Fiber Optic Receiver

Table 7 Fiber Optic Datalink

Model

Fiber
Type

1

1. MMF = Multimode Fiber / SMF = Single-mode Fiber.

Fiber
Optic
Diameter

Optical
Frequency

Receiver Power

Minimum

Typical
Sensitivity

Saturation

AT-FS211
AT-FS212
AT-FS214
AT-FS215
AT-FS216
AT-FS217

MMF

50/125

1310 nm

-31.8

-34.5

-14.0

MMF

62.5/125

1310 nm

-31.8

-34.5

-14.0

AT-FS212/1

SMF

9/125

1310 nm

-31.0

-31.0

-8.0

AT-FS212/2

SMF

9/125

1310 nm

-35.0

-38.0

0.0

AT-FS212/3

SMF

9/125

1310 nm

-37.0

-37.0

-3.0

AT-FS212/4

SMF

9/125

1550 nm

-37.0

-37.0

-3.0

Model

Fiber Type

Minimum
Power/Link
Budget

Average
Signal
Loss

Minimum
Operating
Distance

1

1. The recommended minimum range is stated in all cases where the maximum transmitter output power exceeds

the receivers saturation level. This is to prevent blinding or burning out of the optical receiver on the far end-node.

Maximum
Operating
Distance

AT-FS211
AT-FS212
AT-FS214
AT-FS215
AT-FS216
AT-FS217

50/125
MMF

13.00

18.70

0

2 km (1.25 mi)

62.5/125
MMF

16.80

22.50

0

2 km (1.25 mi)

AT-FS212/1

9/125 SMF

16.00

19.50

0

15 km (9.4 mi)

AT-FS212/2

9/125 SMF

30.00

35.00

0

40 km (25 mi)

AT-FS212/3

9/125 SMF

33.00

35.00

15 km
(9.3 mi)

70 km
(43.4 mi)

AT-FS212/4

9/125 SMF

34.00

35.00

40 km
(24.8 mi)

100 km
(62 mi)