Allied Telesis AT-FS217 User Manual
Page 29

AT-FS21x and AT-FS212/x Series Installation Guide
19
Table 6 Fiber Optic Receiver
Table 7 Fiber Optic Datalink
Model
Fiber
Type
1
1. MMF = Multimode Fiber / SMF = Single-mode Fiber.
Fiber
Optic
Diameter
Optical
Frequency
Receiver Power
Minimum
Typical
Sensitivity
Saturation
AT-FS211
AT-FS212
AT-FS214
AT-FS215
AT-FS216
AT-FS217
MMF
50/125
1310 nm
-31.8
-34.5
-14.0
MMF
62.5/125
1310 nm
-31.8
-34.5
-14.0
AT-FS212/1
SMF
9/125
1310 nm
-31.0
-31.0
-8.0
AT-FS212/2
SMF
9/125
1310 nm
-35.0
-38.0
0.0
AT-FS212/3
SMF
9/125
1310 nm
-37.0
-37.0
-3.0
AT-FS212/4
SMF
9/125
1550 nm
-37.0
-37.0
-3.0
Model
Fiber Type
Minimum
Power/Link
Budget
Average
Signal
Loss
Minimum
Operating
Distance
1
1. The recommended minimum range is stated in all cases where the maximum transmitter output power exceeds
the receivers saturation level. This is to prevent blinding or burning out of the optical receiver on the far end-node.
Maximum
Operating
Distance
AT-FS211
AT-FS212
AT-FS214
AT-FS215
AT-FS216
AT-FS217
50/125
MMF
13.00
18.70
0
2 km (1.25 mi)
62.5/125
MMF
16.80
22.50
0
2 km (1.25 mi)
AT-FS212/1
9/125 SMF
16.00
19.50
0
15 km (9.4 mi)
AT-FS212/2
9/125 SMF
30.00
35.00
0
40 km (25 mi)
AT-FS212/3
9/125 SMF
33.00
35.00
15 km
(9.3 mi)
70 km
(43.4 mi)
AT-FS212/4
9/125 SMF
34.00
35.00
40 km
(24.8 mi)
100 km
(62 mi)