beautypg.com

Allied Telesis AT-MC16 User Manual

Page 24

background image

14

q

Refer to Table 5 for the twisted pair cabling specifications.

Table 5 Twisted Pair Port Specifications

q

Refer to Table 6 for the thinnet cabling specifications.

Table 6 Thinnet Port Specifications

q

Refer to Table 7 and Table 8 for the fiber optic cabling specifications.

Table 7 Fiber Optic Port Specifications (Full-duplex)

Model

Cable

Maximum Operating Distance

All models

Shielded or unshielded Category 3
or better

100 m (328 ft)

Model

Cable

Maximum Operating Distance

AT-MC15

Shielded or unshielded Category 3
or better

185 m (606 ft)

Model

Connector

Cable

Maximum Operating
Distance

Maximum
Allowable Loss
Budget

AT-MC13

ST

62.5/125 micron
multimode

2 km (1.2 mi)

1

1. Maximum operating distance over multimode fiber is 2 km (1.2 mi) if the maximum measured optical loss budget

is less than 20 dB’s when measured at 850 nm optical wavelength.

20 dB at 850 nm

AT-MC14

SC

62.5/125 micron
multimode

2 km (1.2 mi)

1

20 dB at 850 nm

AT-MC16

ST

9/125 micron
single-mode

15 km (9.3 mi)

13 dB at 1310 nm

This manual is related to the following products: