Interface Info

Displays port statistics such as the number of frames received and transmitted on the port,
bytes received and transmitted on the port, and port status.

Note

- The Interface Info sub-menu option displays port parameters for 20 ports. By default,

the Administration Status parameter is set to 'up' for the first four ports and 'down' for the rest
of the ports. For ports 1 to 3, the Administration Status parameter cannot be configured. Its
value is fixed to 'up'. For ports 5 to 12, valid MIB Set values for the Administration Status
parameter are 'up' and 'down'. Attempting to set this parameter to any other value will result
in the error message: "The error occurred with 'Set' operation. Error: bad value."

Note

- The Administration Status parameter always returns to its default value whenever the

device is restarted.


Error Statistics

Displays error statistics for the port.

Note

- The current firmware version returns 'noSuchName' for the Ethernet Chip Set

parameter.