Error Statistics
Displays error statistics.
Detail Info
Displays detailed port information such as duplex mode.
Note
- Setting the Port Reset parameter to 'reset' will not reset the port's attributes.
Note
- Valid MIB Set values for the Port Flow Control parameter are 'disable', 'transmit-
only', 'receive-only', and 'transmit-and-receive'. However, the current firmware version does
not allow this parameter to be set to 'transmit-only' and 'receive-only' for the following ports:
•
Expansion module ports
•
GBIC ports on the AT-8024GB
•
Fiber optic ports on the AT-8026FC
Note
- For AT-8024GB devices, the current firmware version does not allow the Port Speed
and Mode parameter of the GBIC ports to bet set to '1Gbps half-duplex'.
Note
- Valid MIB Set Values for the Port State parameter are 'enabled' and 'disabled'.
Attempting to set this parameter to any other value will result in the error message: "The
error occurred with 'Set' operation. Error: bad value."
Note
- The current firmware version does not allow the Port Name parameter to be
configured. Attempting to configure this parameter will result in the error message: "The
error occurred with 'Set' operation. Error: noSuchName".
Spanning Tree Info
Displays the port's spanning tree parameters.
Note
- Setting a port's Port parameter to 'disabled' does not automatically set the Port State
parameter under Detail Info to 'disabled'. As a result, the port's image may not turn red as
expected.
Enable
Enables the port.
Note
- Under the Sun Solaris platform, the AT-View Plus Device Manager application may
terminate abnormally if multiple ports have been selected and each dialog box with the
message "May I set 'atiswitchPortState.n' to up" is clicked one after the other.
Disable
Disables the port.