beautypg.com

Connect the ground – Allied Telesis AT-EN646MOD Enclosure User Manual

Page 24

background image

AT-EN646MOD Installation Guide

24

Chapter 3: Enclosure Installation

Secure the Entrance (Replace/Seal the Grommet and Install Tie-Down)

1. Take the grommet that you removed and cut a notch at the bottom so that the drop and ground

wire can go through when the grommet is replaced.

2. Place the grommet back (with the notch at the bottom) and seal the grommet with tape (not

provided) and silicone sealant (not provided). Refer to Figure 19.

Caution

The grommet must be sealed so that the unit can operate correctly in an outside environment.

3. Insert a UV-rated wire tie (not provided) through the slots at the bottom of the entrance as shown in

Figure 19.

Figure 19. Sealing Grommet and Inserting Tie-Down

4. Secure the fiber cable and ground wire to the enclosure by wrapping the wire tie around the cords and

cutting off the excess wire tie.

Connect the Ground

1. Connect the other end of the ground wire to the building’s grounding electrode, according to local and

national electrical codes.

All Countries: Install product in accordance with local and
National Electrical Codes.