AT-EN646MOD Installation Guide

22

Chapter 3: Enclosure Installation

Note

Make sure that the fiber optic cable is not secured by either clamp.

10. Position the cable so that the opened shielding goes under the strength member clamp and the closed

portion of the cable is about 0.25 in. (0.7 cm) beyond the drop cable clamp posts as shown in Figure 16

Figure 16. Positioning the Cable

11. Tighten the Kepnuts on the strength member clamp to between 10 and 12 in-lbs to ground the shielding.

12. Replace the bar, washers, and Kepnuts on the posts of the drop cable clamp and tighten the Kepnuts to

secure the cable, as shown in Figure 17, to between 10 and 12 in-lbs.

Figure 17. Armored Drop Cable Secured to the Grounding Plate