AT-MC601, AT-MC602 Installation and User’s Guide

48

Verify that the ACT LED for each twisted pair port is ON. If a ACT LED is
OFF, do the following:

❑ Verify that the end node connected to the port is powered ON and is

operating properly.

❑ Check that the twisted pair cable is securely connected to the port on

the network extender and to the port on the end node.

❑ Make sure that the twisted pair cable does not exceed 100 meters

(328 feet).

❑ Verify that you are using the appropriate category of twisted pair

cable: Category 3 or better for 10 Mbps operation, Category 5 and
Category 5E for 100 Mbps operation.

❑ Make sure that the operating parameters of the port on the network

extender are compatible with the end node to which the port is
connected.

Error Messages

When using the configuration software, you may encounter the following
error messages:

❑ “

No answer from device

,” as shown in Figure 32

Figure 32 No Answer Error Message

This error message may occur when your computer is not
responding, in which case you should re-start your computer and try
again.

❑ “

Communication error: the program will be closed. Verify serial

connection and restart the program

,” as shown in Figure 33

Figure 33 Communication Error Message