Type – ADC CRA-C User Manual
Page 55
Configure and View Status
Megabit Modem CRA-C User Manual
47
ADSL Alarm History.
The ADSL Alarm History screen consists of five
columns. Table 14 describes the information found in each column.
Type
4
4
on the ADSL Menu to open the ADSL Alarm History screen.
0 9 / 0 8 / 9 7 P A I R G A I N T E C H N O L O G I E S 0 8 :4 7 : 5 4
A T U - C A D S L M E G A B I T M O D E M T E R M I N A L 0 1 . 0 1
A D S L A L A R M H I S T O R Y
T y p e F i r s t L a s t Cu r r e nt D ur at i on (s )
L O F , D O W N 0 9 / 0 8 / 9 7 - 1 6 : 5 0 : 4 6 0 9 / 0 8 / 9 7 - 1 7 : 5 3 : 2 0 OK
L O F , U P 0 9 / 0 8 / 9 7 - 1 6 : 5 0 : 4 6 0 9 / 0 8 / 9 7 - 1 7 : 5 3 : 2 0 OK
M A R G I N , D O W N OK
M A R G I N , U P OK
E S , D O W N OK
E S , U P OK
S E S , D O W N OK
S E S , U P OK
S E L F T E S T OK
L A S T C L E A R E D : 0 9 / 0 8 / 9 7 - 1 6 : 5 0 : 4 5
( C ) l e a r ( R ) e t u r n ( M ) a i n
E N T E R C H O I C E - - >
Type
C
C
to update the first and last date/time stamps and clear the time to 0.
The Alarm History data is lost when the Megabit
Modem CRA-C is turned off.
Table 14. ADSL Alarm History Screen Columns
Name
Description
Type
Identifies local, remote, and ADSL link alarms.
LOF: Loss of frame failure
MARGIN: Low SNR margin alarm
ES: Excessive errored seconds
SES: Severely errored seconds
SELF: Self test
First
Lists the first time an alarm is detected.
Last
Lists the last time an alarm was detected.
Current
Identifies the current status of the alarm.
Durations
Indicates the total accumulated number of seconds the
system was in alarm condition since the last clear.