background image

Configure and View Status

Megabit Modem CRA-C User Manual

47

ADSL Alarm History.

The ADSL Alarm History screen consists of five

columns. Table 14 describes the information found in each column.

Type

4

4

on the ADSL Menu to open the ADSL Alarm History screen.

0 9 / 0 8 / 9 7 P A I R G A I N T E C H N O L O G I E S 0 8 :4 7 : 5 4

A T U - C A D S L M E G A B I T M O D E M T E R M I N A L 0 1 . 0 1

A D S L A L A R M H I S T O R Y

T y p e F i r s t L a s t Cu r r e nt D ur at i on (s )

L O F , D O W N 0 9 / 0 8 / 9 7 - 1 6 : 5 0 : 4 6 0 9 / 0 8 / 9 7 - 1 7 : 5 3 : 2 0 OK

L O F , U P 0 9 / 0 8 / 9 7 - 1 6 : 5 0 : 4 6 0 9 / 0 8 / 9 7 - 1 7 : 5 3 : 2 0 OK

M A R G I N , D O W N OK

M A R G I N , U P OK

E S , D O W N OK

E S , U P OK

S E S , D O W N OK

S E S , U P OK

S E L F T E S T OK

L A S T C L E A R E D : 0 9 / 0 8 / 9 7 - 1 6 : 5 0 : 4 5

( C ) l e a r ( R ) e t u r n ( M ) a i n

E N T E R C H O I C E - - >

Type

C

C

to update the first and last date/time stamps and clear the time to 0.

The Alarm History data is lost when the Megabit
Modem CRA-C is turned off.

Table 14. ADSL Alarm History Screen Columns

Name

Description

Type

Identifies local, remote, and ADSL link alarms.

LOF: Loss of frame failure
MARGIN: Low SNR margin alarm
ES: Excessive errored seconds
SES: Severely errored seconds
SELF: Self test

First

Lists the first time an alarm is detected.

Last

Lists the last time an alarm was detected.

Current

Identifies the current status of the alarm.

Durations

Indicates the total accumulated number of seconds the
system was in alarm condition since the last clear.