3. Wind Transmitter (cont.)

-

Remove the bottom portion of the black bracket on the back of the Wind
transmitter case, by loosening the four black screws.

-

Place the Wind transmitter case on the horizontal section of the formed wind
direction mast with the antenna situated above the mast arm.

-

Place the bottom portion of the black bracket behind the mast arm and secure
it in place with the four black screws that were removed.

-

Secure both sensor stub masts to your antenna mast (not supplied) with the
two hose clamps provided.

-

Open the Wind transmitter case by lifting the two thumb latches, and place the
circuit board Jumper in the test position (

see Diagram C

). This will ensure that

the Receiver recognizes the Wind transmitter when batteries are eventually
inserted.


Jumper






Normal Position








Test Position

Diagram C




IV. Transceiver Testing & Sensor Installation (please follow directions in the order shown)

A. Instrument Display

-

Move the instrument display and the individual sensors nearby the desired
installation location (the display may lie on a table or floor for testing purposes).

o

This step is necessary to determine whether or not proper signals can
be obtained for each component, prior to final installation.

-

Connect the AC adaptor(s) provided, to the instrument(s).

o

If you have more than 1 instrument, wire 1 AC adaptor to each
instrument.

-

Plug in all the AC adaptors.

SOLDER SIDE