TROUBLE-SHOOTING

NO SIGNAL FROM RAIN TRANSMITTER

SYMPTOM:

REMEDY:

(Instrument has received, then lost sensor signal)

REMOVE OUTER

CASE BY LOOSENING

FOUR SCREWS

SLIP CAP OFF

CYLINDER HOUSING

TRANSMITTER

CIRCUIT BOARD

REMOVE

TRANSMITTER

CIRCUIT BOARD

FROM CYLINDER

TEST

MODE

OPERATING

MODE

JUMPER

JUMPER

SET JUMPER TO

TEST MODE BY

COVERING BOTH PINS

-Re-install the AA Alkaline batteries in the RAIN TRANSMITTER once the jumper has been moved.
-Check LED on receiver to make sure it is blinking ORANGE every 4 seconds.
-Check the instruments to see if the error has been corrected.
-Unlike the WIND and TEMPERATURE TRANSMITTERS, the RAIN TRANSMITTER will not automatically
exit test MODE after 15 minutes. Therefore, you must take the rain transmitter out of test mode manually. To
do so: remove the batteries, then move the jumper on the RAIN TRANSMITTER circuit board back to covering
only one pin of the 2-pin terminal (it does not matter which pin is covered). Re-install the batteries and cover.
-If the instrument continues to display the error code, call Maximum for further assistance.

BATTERY

COMPARTMENT

-Test and replace (if necessary) the AA Alkaline batteries in the RAIN TRANSMITTER.
-Put the RAIN TRANSMITTER into TEST MODE by removing the batteries, then moving the jumper on the
RAIN TRANSMITTER circuit board to cover both pins of the 2-pin terminal.

-Merlin Reads “NS “ (No Direction LED’s illuminated).
-Mystic Reads “NS “ (No Temperature or Pressure LED’s illuminated).