Rainwatch, Installation (cont.), Wall – Maximum Rainwatch (pre-2012) User Manual
Page 2

RAINWATCH
INSTALLATION (CONT.)
30 Samuel Barnett Boulevard
New Bedford, MA 02745
(508) 995-2200
6
Connect the wires from the AC Adaptor
cord to terminals #1 and #2. The polarity
does not matter.
7
8
9
10
11
Connect the collector wires to terminals
#4 and #5. The polarity does not matter.
Using a quality alkaline type 9V battery,
connect the battery to the battery snap.
Seat the battey in the compartment.
AC
ADAPTOR
CABLE-HOLE
WALL
PRE-DRILLED PANEL
SCREW
FEED-THRU-HOLE
SCREW
Mount the Brass Readout directly over the Feed-Thru-Hole
to avoid crimping the wire under the lip. We recommend
mounting the Readout on one of our pre-drilled and
centered panels.
Plug in the AC adaptor. The display
should now light up.
Reset the display by holding the
reset button for six seconds.