beautypg.com

Is programmable from 0 to 7 – Wesley BC-6200-8SA User Manual

Page 33

background image

27

Curtis 1268 Manual,

Rev. D

WARNING OPTION
The warning option parameter sets the output pattern—flash or solid—of the
external LED (Pin 22) and the warning beep conditions during anti-rollback
and overvoltage (Pin 19).

WARNING OPTION

is programmable from 0 to 7:

EXTERNAL

LED

ANTI

-

ROLLBACK

OVERVOLTAGE

SETTING

OUTPUT

BEEP

BEEP

0

flash

no

no

1

flash

no

yes

2

flash

yes

no

3

flash

yes

yes

4

solid

no

no

5

solid

no

yes

6

solid

yes

no

7

solid

yes

yes

3 — PROGRAMMABLE PARAMETERS: Fault Parameters