Is programmable from 0 to 7 – Wesley BC-6200-8SA User Manual
Page 33
27
Curtis 1268 Manual,
Rev. D
WARNING OPTION
The warning option parameter sets the output pattern—flash or solid—of the
external LED (Pin 22) and the warning beep conditions during anti-rollback
and overvoltage (Pin 19).
WARNING OPTION
is programmable from 0 to 7:
EXTERNAL
LED
ANTI
-
ROLLBACK
OVERVOLTAGE
SETTING
OUTPUT
BEEP
BEEP
0
flash
no
no
1
flash
no
yes
2
flash
yes
no
3
flash
yes
yes
4
solid
no
no
5
solid
no
yes
6
solid
yes
no
7
solid
yes
yes
3 — PROGRAMMABLE PARAMETERS: Fault Parameters
This manual is related to the following products:
- BC-6200-8CA BC-6000-8SA BC-6000-8CA BC-6200-8SAC BC-6250-8SA BC-6250-8CA BC-620-8SA BC-620-8CA BC-600-8SA BC-600-8CA BC-625-8SA BC-625-8CA SCT-7750-8AC SCT-7750-8SA SCT-7750-8CA SCT-7750-6AC SCT-7750-8AC-MTR SCT-7750-8CA-MTR PC-325-6SA PC-325-6CA PMT-5000-8CA PMT-5000-8SA PMT-4500-8SA PMT-4500-8CA SC-775-8CA SC-775-8SA SC-775-8AC