FIELD MAP END / NEG FLD MAP EN
The field map end parameter defines the armature current at which the field
map clamps to the

FIELD MAX

value (see current limit parameters).

Care should be taken to ensure that high

FIELD MAP END

values do not move

the motor’s operating characteristics outside its safe commutation region.

FIELD RAMP / NEG FLD RAMP
The field ramp parameter defines the shape of the field map curve. It is set as
a percentage of the field current between the

FIELD MIN

and

FIELD MAX

values.

As shown in Figure 9, the

FIELD RAMP

parameter sets the field current at

the armature current that is halfway between the

FIELD MAP START

current and the

FIELD MAP END

current. This halfway point is called the Field Map Midpoint.

3 — PROGRAMMABLE PARAMETERS: Field Mapping Parameters

Fig. 9

Field map structure.

With

FIELD RAMP

set at 50% and

FIELD MAP START

set at zero, the motor’s field

current increases linearly with increasing armature current—thus emulating a
series wound motor. Decreasing the

FIELD RAMP

setting reduces the field current

at a given armature current, i.e., it weakens the field. As the field current is
reduced, the motor will be able to achieve higher speeds.

Care should be taken to ensure that excessively low

FIELD RAMP

values do not

move the motor’s operating characteristics outside its safe commutation region.

FIELD DIR SWAP
The field direction swap parameter changes the polarity of the motor field
output with respect to the direction inputs. If the motor field wiring is reversed
at the motor or controller field terminals, the motor rotation may cause the
vehicle to move in the opposite direction from the direction command. The

FIELD DIR SWAP

parameter provides a way to swap the field direction without

physically changing the wiring.

FIELD DIR SWAP

= off

(default setting, for wiring shown in Figure 3)

Field current flows from F2 » F1 in the Forward direction.

FIELD DIR SWAP

= on

Field current flows from F1 » F2 in the Forward direction.