beautypg.com

Wesley BC-6200-8SA User Manual

Page 30

background image

24

Curtis 1268 Manual,

Rev. D

The field mapping parameters determine how much field current is applied for
a given armature current.

M1/M2 FWD FIELD MIN
The forward minimum field current limit parameter defines the minimum
allowed current in the motor’s field winding when the vehicle is traveling in
the forward direction. Its setting may affect the vehicle’s maximum speed and,
to some extent, the smoothness with which the vehicle starts and transitions
between drive and regen. If

FWD FIELD MIN

is set high, the vehicle’s top speed will

be reduced, but torque bumps may be evident when the vehicle is inched or
changes direction.

One of the greatest advantages of the

FIELD MIN

parameter is that it will

prevent uncontrolled acceleration when the vehicle goes down ramps or when
it is unloaded from trucks, etc.

REV FIELD MIN
The reverse minimum field current limit parameter defines the minimum
allowed current in the motor’s field winding when the vehicle is traveling in
the reverse direction.

FIELD MAX
The maximum field current limit parameter defines the maximum allowed
current in the motor’s field winding. Its setting will determine the motor’s
maximum torque during drive operation, and will limit the power dissipation
in the field winding itself.

NEG FIELD MAX
The negative maximum field current limit parameter defines maximum al-
lowed current in the motor’s field winding during regen braking.

FLD MAP START / NEG FLD MAP ST
The field map start parameter defines the armature current at which the field
current starts to increase from the

FIELD MIN

value (see current limit parameters).

The negative field map start parameter works similarly; it defines the negative
armature current at which the field current starts to increase from the

FIELD MIN

value.

Care should be taken to ensure that high

FIELD MAP START

values do not

move the motor’s operating characteristics outside its safe commutation area.

3 — PROGRAMMABLE PARAMETERS: Field Mapping Parameters