3 03002 rm young wind sentry wind set, 1 03002 mounted to the mast, 2 03002 mounted to a cm200-series crossarm – Campbell Scientific UT20 and UT30 Tower-based Weather Stations User Manual
Page 49: 03002 rm young wind sentry wind set, 03002 mounted to the mast, 03002 mounted to a cm200-series crossarm, 16. 03002 mounted to a cm200-series crossarm

UT20 and UT30 Tower-based Weather Stations
8.5.3 03002 RM Young Wind Sentry Wind Set
The 03002 can be mounted directly to the mast, or to a crossarm.
8.5.3.1 03002 Mounted to the Mast
1. Slide the crossarm mounting bracket onto the mast. Orient the crossarm so
the vane end points north, and tighten the band clamp (see Section 8.5.18,
Wind Direction Sensor Orientation, for final calibration).
2. Attach the cup assembly to the anemometer shaft using the Allen wrench
provided.
8.5.3.2 03002 Mounted to a CM200-Series Crossarm
Mount the 03001 to the crossarm as shown in FIGURE 8-16.
1. Attach the CM220 bracket on the crossarm via the U-bolt and nuts.
2. Position the top of the mounting post 5 inches above the CM220 bracket
and tighten the set screws.
3. Slide the crossarm mounting bracket onto the mounting post. Orient the
crossarm so the vane end points north, and tighten the band clamp (see
Section 8.5.18, Wind Direction Sensor Orientation, for final calibration).
4. Attach the cup assembly to the anemometer shaft using the Allen wrench
provided.
FIGURE 8-16. 03002 mounted to a CM200-series Crossarm
39