2 sensor mounting brackets, 1 cm202, com202ss, cm203, cm204, cm204ss, or cm206, 2 gill radiation shields – Campbell Scientific UT20 and UT30 Tower-based Weather Stations User Manual
Page 28: 1 41303-5a, 41003-5, 41005-5, 3 solar radiation mounts, 1 cm225 solar radiation stand, Sensor mounting brackets, Cm202, com202ss, cm203, cm204, cm204ss, or cm206, Gill radiation shields, 41303-5a, 41003-5, 41005-5

UT20 and UT30 Tower-based Weather Stations
FIGURE 7-13. Tower grounding clamp
7.2 Sensor Mounting Brackets
Sensor mounting brackets provide a means of mounting the sensors to the
tower. General orientation of the mounting brackets is shown in FIGURE
7.2.1 CM202, COM202SS, CM203, CM204, CM204SS, or CM206
1. Attach the crossarm at the desired height via the provided U-bolts and nuts
7.2.2 Gill Radiation Shields
7.2.2.1 41303-5A, 41003-5, 41005-5
1. Attach the radiation shield to the tower leg, tower mast, or CM200-series
crossarm with the U-bolt and nuts provided. If attaching to the tower leg
or mast, place U-bolt in the radiation shield’s side holes. If attaching to a
crossarm, place the U-bolt in the radiation shield’s bottom holes.
7.2.3 Solar Radiation Mounts
7.2.3.1 CM225 Solar Radiation Stand
1. If using a LI200X, LI190SP, or CS300, attach the LI2003S or 18356
leveling base to the CM225 using the three screws provided.
2. Attach the CM225 to a tower leg, mast, or CM200-series crossarm. If
attaching to a tower leg or mast, place the U-bolt in the CM225’s side
holes. If attaching to a crossarm, place the U-bolt in the CM225’s bottom
holes (FIGURE 7-16).
Wire to
Ground Rod
Wire to
Enclosure
Clamp
18