Campbell Scientific TX312 High Data Rate GOES Transmitter User Manual
Page 64

Appendix D. RAWS-7 Data Format
D-16
3: Z=X*F (P37)
1: 35
X Loc [ Batt_load ]
2: .1
F
3: 35
Z Loc [ Batt_load ]
4: Z=X*F (P37)
1: 36
X Loc [ GPSAccTm ]
2: 10
F
3: 36
Z Loc [ GPSAccTm ]
5: End (P95)
; Set datalogger clock to GPS time once a day
6: If time is (P92)
1: 150
Minutes (Seconds --) into a
2: 1440
Interval (same units as above)
3: 30
Then
Do
7: HDR GOES Status (P127)
1: 0
Read
Time
2: 44
Result Code Loc [ time_rc ]
8: If (X<=>F) (P89)
1: 44
X Loc [ time_rc ]
2: 4
<
3: 1
F
4: 30
Then
Do
9: If (X<=>F) (P89)
1: 45
X Loc [ GPS_hour ]
2: 3
>=
3: 0
F
4: 30
Then
Do
10: If (X<=>F) (P89)
1: 45
X Loc [ GPS_hour ]
2: 4
<
3: 24.1
F
4: 30
Then
Do
11: Set Real Time Clock (P114)
1: 0
Set Hr,Min,Sec from locations
2: 45
Loc [ GPS_hour ]
12: End (P95)
13: End (P95)
14: End (P95)
15: End (P95)
16: If time is (P92)
1: 0
Minutes (Seconds --) into a
2: 180
Interval (same units as above)
3: 10
Set Output Flag High (Flag 0)