beautypg.com

Campbell Scientific TX312 High Data Rate GOES Transmitter User Manual

Page 59

background image

Appendix D. RAWS-7 Data Format

D-11


; FIRST HOUR
; First hour (column 1) is the top of the first hour after
; the transmit window.

; Move hourly values to "old" place holders
; Input storage is used to hold hourly data until
; 3 hours of RAWS-7 data has been written to final storage
; and sent to the transmitter
54: If time is (P92)
1: 120

Minutes (Seconds --) into a ;changed 3/31/0

2: 180

Interval (same units as above)

3: 10

Set Output Flag High (Flag 0)


55: Set Active Storage Area (P80)
1: 3

Input

Storage

Area

2: 16

Loc [ MaxWD_Old ]


56: Sample (P70)
1: 1

Reps

2: 13

Loc [ WDHrMxWS ]


57: Set Active Storage Area (P80)
1: 3

Input

Storage

Area

2: 19

Loc [ MaxWS_Old ]


58: Sample (P70)
1: 1

Reps

2: 12

Loc [ MaxHrWS ]


59: Set Active Storage Area (P80)
1: 3

Input

Storage

Area

2: 22

Loc [ SRad_Old ]


;Solar radiation is high resolution format
60: Resolution (P78)
1: 1

High

Resolution


61: Average (P71)
1: 1

Reps

2: 9

Loc [ SRad ]


62: Resolution (P78)
1: 0

Low

Resolution


; Fuel Moisture
63: Set Active Storage Area (P80)
1: 3

Input

Storage

Area

2: 25

Loc [ FM_Old ]


64: Sample (P70)
1: 1

Reps

2: 28

Loc [ FuelM ]