Appendix D. RAWS-7 Data Format
D-8
; if no fuel temp sensor,
; load 999 for data value
26: If (X<=>F) (P89)
1: 7
X Loc [ FuelT ]
2: 4
<
3: -35
F
4: 30
Then
Do
27: Z=F (P30)
1: 999
F
2: 0
Exponent
of
10
3: 7
Z Loc [ FuelT ]
28: End (P95)
29: If (X<=>F) (P89)
1: 7
X Loc [ FuelT ]
2: 3
>=
3: 55
F
4: 30
Then
Do
30: Z=F (P30)
1: 999
F
2: 00
Exponent
of
10
3: 7
Z Loc [ FuelT ]
31: End (P95)
; Calculate program signature once a day
32: If time is (P92)
1: 0
Minutes (Seconds --) into a
2: 1440
Interval (same units as above)
3: 30
Then
Do
33: Signature (P19)
1: 2
Loc [ Prog_Sig ]
34: End (P95)
; Calculate and hold 10 minute averages for Wspd and Wdir
; Values are written to input locations 10 and 11 (Avg10WS, Avg10WD)
35: If time is (P92)
1: 0
Minutes (Seconds --) into a
2: 10
Interval (same units as above)
3: 10
Set Output Flag High (Flag 0)
; Direct output processing to input locations
36: Set Active Storage Area (P80)
1: 3
Input
Storage
Area
2: 10
Loc [ Avg10WS ]