Campbell Scientific TX312 High Data Rate GOES Transmitter User Manual
Page 63
Appendix D. RAWS-7 Data Format
D-15
95: Do (P86)
1: 10
Set Output Flag High (Flag 0)
; Set resolution high
96: Resolution (P78)
1: 1
High
Resolution
; Write row 10 to final storage
97: Sample (P70)
1: 3
Reps
2: 22
Loc [ SRad_Old ]
; set resolution low
98: Resolution (P78)
1: 0
Low
Resolution
; Copy row 10 to transmitter
99: Data Transfer to HDR GOES (P126)
1: 0
Self-Timed/Append
2: 8
ASCII
xxxxx
Format
3: 14
Result Code Loc [ P126_RC ]
100: Do (P86)
1: 10
Set Output Flag High (Flag 0)
; Write row 11 to final storage
101: Sample (P70)
1: 3
Reps
2: 25
Loc [ FM_Old ]
; Copy row 11 to transmitter
102: Data Transfer to HDR GOES (P126)
1: 0
Self-Timed/Append
2: 7
ASCII
xxx
Format
3: 14
Result Code Loc [ P126_RC ]
103: End (P95)
*Table 2 Program
02: 600
Execution Interval (seconds)
1: If time is (P92)
1: 0
Minutes (Seconds --) into a
2: 180
Interval (same units as above)
3: 30
Then
Do
2: HDR GOES Status (P127)
1: 2
Read Last Message Status
2: 30
Result Code Loc [ L_Msg_RC ]