Campbell Scientific TX312 High Data Rate GOES Transmitter User Manual
Page 62
Appendix D. RAWS-7 Data Format
D-14
; xxx xxx xxx
Dir Max WS : Oldest to the left
; xxx xxx xxx
Max WS : Oldest to the left
; xxxxx xxxxx xxxxx
Avg SRad : Oldest to the left
; xxx xxx xxx
fuel mois :
Oldest to the left
;P126 Instruction, Parameter 2 Options
; 3 RAWS-7 Output
; 4 xxx.x ASCII Output
; 5 xx.xx ASCII Output
; 6 x.xxx ASCII Output
; 7 xxx ASCII Output
; 8 xxxxx ASCII Output of a high resolution value
; No less than 5 minutes before transmit time, data is
; written to final storage and copied to the transmitter
87: If time is (P92)
1: 65
Minutes (Seconds --) into a
2: 180
Interval (same units as above)
3: 30
Then
Do
88: Do (P86)
1: 10
Set Output Flag High (Flag 0)
89: Set Active Storage Area (P80)
1: 1
Final Storage Area 1
2: 123
Array
ID
; Write first row after RAWS-7 data, Row 8.
; Direction of max wind speed
90: Sample (P70)
1: 3
Reps
2: 16
Loc [ MaxWD_Old ]
; Copy Row 8 to transmitter
91: Data Transfer to HDR GOES (P126)
1: 0
Self-Timed/Append
2: 7
ASCII
xxx
Format
3: 14
Result Code Loc [ P126_RC ]
92: Do (P86)
1: 10
Set Output Flag High (Flag 0)
; Write row 9 to final storage, Max Wind Speed
93: Sample (P70)
1: 3
Reps
2: 19
Loc [ MaxWS_Old ]
; Copy to transmitter
94: Data Transfer to HDR GOES (P126)
1: 0
Self-Timed/Append
2: 7
ASCII
xxx
Format
3: 14
Result Code Loc [ P126_RC ]