Campbell Scientific TX312 High Data Rate GOES Transmitter User Manual
Page 53
Appendix D. RAWS-7 Data Format
D-5
; Measure Fuel Moisture
; Wiring:
; Power enable: C8
; Signal: SE 12
4: Period Average (SE) (P27)
1: 1
Reps
2: 4
200 kHz Max Freq @ 2 V Peak to Peak, Period Output
3: 12
SE
Channel
4: 10
No.
of
Cycles
5: 5
Timeout (units = 0.01 seconds)
6: 28
Loc [ FuelM ]
7: .001
Mult
8: 0
Offset
5: Do (P86)
1: 58
Set Port 8 Low
; Measure temperature and RH (HMP45C-L)
6: Excitation with Delay (P22)
1: 1
Ex
Channel
2: 0
Delay W/Ex (units = 0.01 sec)
3: 15
Delay After Ex (units = 0.01 sec)
4: 0
mV
Excitation
7: Volt (SE) (P1)
1: 1
Reps
2: 25
2500 mV 60 Hz Rejection Range
3: 2
SE
Channel
4: 3
Loc [ AirTemp ]
5: .1
Mult
6: -40
Offset
8: Volt (SE) (P1)
1: 1
Reps
2: 25
2500 mV 60 Hz Rejection Range
3: 1
SE
Channel
4: 4
Loc [ RH ]
5: .1
Mult
6: 0
Offset
; Measure wind speed (03001-L)
9: Pulse (P3)
1: 1
Reps
2: 1
Pulse
Channel
1
3: 21
Low Level AC, Output Hz
4: 5
Loc [ Wspd ]
5: 1.677
Mult
;
MPH
6: 0.4
Offset