Appendix C. CR3000 Program for Measuring Pt-100 Temperature Sensor
'CR3000 Series Dat logger
a
'
'CNR4 program 
'This program meas res CNR4 four-component net radiometer 
u
'This program also measures the Pt-100 sensor inside the CNR4
' 
'User must enter the sensitivity values for all four probes in the program and 
save/compile 
'prior to download ng it to the datalogger.
i
'Search for the text string "unique" to find places to enter the sensitivity values. 
' 
 
'Wiring Instructions 
' 
'ANALOG CHANNELS 
'1H CNR4 Pyranometer Upper signal (red) 
'1L CNR4 Pyranometer Upper signal reference (blue) 
'gnd jumper to 1L 
' 
'2H CNR4 Pyranometer Lower signal (white) 
'2L CNR4 Pyranometer Lower signal reference (thin black) 
'gnd jumnper to 2L 
' 
'3H CNR4 Pyrgeometer Upper signal (grey) 
'3L CNR4 Pyrgeometer Upper signal reference (yellow) 
'gnd jumper to 3L 
' 
'4H CNR4 Pyrgeometer Lower signal (brown) 
'4L CNR4 Pyrgeometer Lower signal reference (green) 
'gnd jumper to 4L 
' CNR4 shield (clear) 
' 
' 
'8H CNR4 PRT (Pt-100) signal (green) 
'8L CNR4 PRT (Pt-100) signal reference (yellow) 
'gnd CNR4 PRT (Pt-100) shield (clear) 
' 
 
'CURRENT EXCITATION 
'IX1 CNR4 PRT (Pt-100) current excitation (grey) 
' 
'IXR CNR4 PRT (Pt-100) current excitation return (brown) 
' 
 
'CNR4 sensor 
Public logger_temp, batt_volt 
Public cnr4(4) 
Alias cnr4(1) = short_up 
Alias cnr4(2) = short_dn 
Alias cnr4(3) = long_up 
Alias cnr4(4) = long_dn 
 
Public cnr4_T_C
'CNR4 thermistor temperature in Celcius
Public cnr4_T_K
'CNR4 thermistor temperature in Kelvin
Public long_up_corr
'Downwelling long-wave radiation with temperature correction
Public long_dn_corr
'Upwelling long-wave radiation with temperature correction
Public Rs_net
'short-wave net radiation
Public Rl_net
'long-wave net radiation
Public albedo
'Albedo
Public Rn
'total net radiation
Units logger_temp = degC 
Units batt_volt = volts 
Units short_up = W/m^2 
Units short_dn = W/m^2 
Units long_up = W/m^2 
Units long_dn = W/m^2 
Units cnr4_T_C = deg_C 
C-2