2.1 Specifications
CM6 Tripod
Maximum height (zero leg extension)
7.5 ft (2.3 m)
Minimum height (full leg extension)
5.5 ft (1.7 m)
Wind Load (Wind Sensors at 2 meters)*
Maximum wind load
100 mph
Gust survival
130 mph
Tripod Leg Diameter (See Table 2-1)
d = diameter
h = height at top of bell reducer
d = 2 (4.834 + (54.5
2
- (h - 42.4)
2
)
0.5
)
CM10 Tripod
Maximum height (zero leg extension)
11 ft (3.4 m)
Minimum height (full leg extension)
7.2 ft (2.2 m)
Wind Load (Wind Sensors at 3 meters)*
No Guy Wires
Maximum
70
mph
Gust survival
100 mph
With Guy Wires
Maximum
120
mph
Gust survival
150 mph
Tripod Leg Diameter (See Table 2-2)
d = diameter
h = height at top of bell reducer
d = 2 (4.834 + (78.75
2
- (h - 62.35)
2
)
0.5
)
*Wind Load data assumes 4.5 ft
2
of area placed at the top of the tripod mast
TABLE 2-1. CM6 Heights and
Leg Diameters
Height mark is 1 1/4 inch above bell reducer
Height (In)
Diameter (In)
70 104
6/8
72 102
3/8
74
99 6/8
76 97
78 93
6/8
TABLE 2-2. CM10 Heights and
Leg Diameters
Height (In)
Diameter (In)
109 138
111 135
1/8
113
131 7/8
115 128
1/2
117 125
2-2
- 014A Met One Wind Speed Sensor (36 pages)
- 020C Wind Direction Sensor (26 pages)
- 024A-L Met One Wind Direction Sensor (30 pages)
- 03001-L R.M. Young Wind Sentry Set (34 pages)
- 03002, 03101, and 03301 R. M. Young Wind Sentry Sensors (40 pages)
- 034A-L WindSet (16 pages)
- 034B-L Met One Windset (34 pages)
- 036, 038 Spark Gapped Junction Box (6 pages)
- 05103, 05103-45, 05106, and 05305 R. M. Young Wind Monitors (30 pages)
- 083E Relative Humidity and Temperature Sensor (22 pages)
- 0871LH1 Freezing Rain Sensor (31 pages)
- 092 Barometric Pressure Sensor (24 pages)
- 10164-L Water Sampler Control Cable for use with Isco and Sigma Autosamplers (18 pages)
- 107-L Temperature Probe (28 pages)
- 108-LC Temperature Probe for MetData1 (12 pages)
- 108-L Temperature Probe (30 pages)
- 109-L Temperature Probe (30 pages)
- 109SS Temperature Probe (32 pages)
- 110PV Surface Temperature Probe (32 pages)
- 21108 RF450 Demo Kit (14 pages)
- 223-L Delmhorst Cylindrical Soil Moisture Block (28 pages)
- 227-L Delmhorst Cylindrical Soil Moisture Block (24 pages)
- 229 Water Matric Potential Sensor and CE4/CE8 (34 pages)
- 237-L Leaf Wetness Sensor (14 pages)
- 247-L Conductivity and Temperature (18 pages)
- 253-L and 257-L (Watermark 200) Soil Matric Potential Sensors (36 pages)
- 25458 DIN-Rail Terminal Kit (10 pages)
- 255-100 Novalynx Analog Output Evaporation Gauge (16 pages)
- 260-953 Alter-Type Wind Screen for Tipping Bucket Rain Gages (14 pages)
- 27106T Gill Propeller Anemometer (18 pages)
- 30066 Battery Terminal Bus (1 page)
- 380, 385, 380M, 385M Met One Rain Gages (22 pages)
- 3WHB10K 3-Wire Half-Bridge Terminal Input Module (14 pages)
- 43347 RTD Temperature Probe and 43502 Aspirated Radiation Shield (40 pages)
- 4386 Battery Terminal Bus (1 page)
- 4WFB120, 4WFB350, 4WFB1K 4-Wire Full Bridge Terminal Input Module (22 pages)
- 4WFBS120, 4WFBS350, 4WFBS1K 4 Wire Full Bridge Terminal Input Modules (46 pages)
- 4WPB100, 4WPB1K PRT Terminal Input Modules (16 pages)
- 52202 Electrically Heated Rain and Snow Gage (16 pages)
- 9522B Iridium Satellite Modem and COM9522B Interface Modem (46 pages)
- A100LK Anemometer (18 pages)
- A150 Desiccated Case (12 pages)
- A21REL-12 Relay Driver (10 pages)
- A6REL-12 Relay Driver (12 pages)
- AL200 ALERT2 Encoder, Modulator, and Sensor Interface (44 pages)