beautypg.com

14 miscellaneous, 1 introduction, 2 read version number – Matrix Orbital GLK19264-7T-1U User Manual

Page 59: 3 read module type

background image

Description

Reads whatever was written by Write Customer Data.

Remembered

No

14

Miscellaneous

14.1

Introduction

This chapter covers the ’Report Version Number’ and ’Read Module Type’ commands. These commands

can be particularly useful to find out more information about the display module before contacting technical
support.

14.2

Read Version Number

Syntax

Hexadecimal

0xFE 0x36

Decimal

254 54

ASCII

254 “6”

Description

This command will return a byte representing the version of the module,
see the following table as an example:

Hex Value

Version Number

0x19

Version 1.9

0x57

Version 5.7

Remembered

No

14.3

Read Module Type

Syntax

Hexadecimal

0xFE 0x37

Decimal

254 55

ASCII

254 “7”

Matrix Orbital

GLK19264-7T-1U

54