3 INSTALLATION AND OPERATIONS

3.1 Installation

The UPS system is typically rack or shelf mounted in standard traffic cabinets. When determining
how to position the UPS system inside your cabinet, the following requirements MUST be met.

• The installation site MUST maintain an ambient air temperature of less than 165

o

F (74

o

C).

• The air inlets, vents and fan MUST NOT be obstructed or blocked in any way. There MUST

BE clearance around each air-inlet and vent.

• The air should remain free from excessive dust and chemical fumes.
• Total power requirements to be drawn from the UPS must not exceed the rated power of the

UPS.

Please note these items when designing the UPS system’s mounting hardware:

• The front panel is designed to fit in a standard 19" rack. This panel fills a 6-inch slot.

3.2 Preparation

Installation of the PD Series Traffic UPS must be preceded by careful preparation. The following

steps are typical:

• Ensure that the Installation Requirements will be met. (See previous section).
• Read this manual thoroughly.
• Assemble wiring diagrams.