8.3 CLEANING
CARRY OUT THE CLEANING OPERATIONS EVERY WEEK.
It is a good rule to carry out periodical cleaning of the press in order to eliminate
foreign bodies (e.g. dust, extraneous and dirty substances, etc.).
Eliminate all foreign bodies from the piston rod that could damage both the surface
of the rod and the cylinder gaskets.
While cleaning, use detergent substances that are not harmful, do not pollute and
are in conformity with the law.
While cleaning, prevent shaking with hands, wear protective gloves and use brushes
or oilers to lubricate the guides.
Do not use solvents or aggressive acids.
Section 9.0
9.0 MALFUNCTIONING, CAUSES and REMEDIES
9.1 CYLINDER MALFUNCTIONING
* Call Dake Technical Service 1-800-937-3253
CYLINDERS
MALFUNCTION
ORIGIN
REMEDY
The cylinder moves
irregularly
- Air in the pump
- Air in the circuit
- Damage cylinder gaskets
- Damage or worm pump
- Sequence valve jammed
- Delivery pipe clogged or
choked.
- Bleed the air
- Bleed the air
- Replace the gaskets
- Replace the pump
- Recondition seq. valve
- Check pipes
*
*
Cylinder will not move - Cylinder gaskets
completely damaged
- Blocked distributor
- Damaged pump
- Replace
- Recondition distributor
- Recondition or replace
*
*
Cylinder leaks oil
- Head gasket damaged or
worn
- Replace
Cylinder will not press - Lack of pressure from
pump
- Pressure control valve set
low
- Recondition pump
- Set valve
*