PROBLEM

CAUSE

CORRECTION

1. Not tilling level.

A. Depth control cylinders out

of phase.

Rephase cylinders. See page 3-6.

B. Eyebolts not adjusted prop-

erly.

Adjust with wrenches provided.

See Pages 3-8 and 3-9.

C. Gauge wheels not adjusted

properly.

Adjust gauge wheels so they ride

freely on top of the ground.

D. Hard Soils conditions.

Use different tillage tool or perform

multiple passes, starting at less

depth.

2. Not pulling straight.

A. Chisel plow not tilling level. See “Not tilling level” above.

3. Inconsistent tillage

depth.

A. Excessive travel speed.

Reduce speed.

B. Hard soil conditions.

Use different tillage tool or perform

multiple passes, starting at less

depth.

C. Deep furrows.

Travel across field furrows at an

angle.

4. Plugging.

A. Working in extremely heavy

trash.

If equipped with mounted harrows,

reduce aggressiveness of harrows

or lock harrows in the up position.

B. Tillage tool (spike, sweep,

etc.) causing plugging.

Change type of tool. Make sure

twisted spikes are not throwing

soil towards wheels.

5. Poor penetration.

A. Machine not running level

front to back.

Adjust eyebolts on front center

wheel assembly.

B. Gauge wheels adjusted

improperly.

Adjust gauge wheels so they ride

freely on top of the ground.

C. Hard soil conditions.

Use different tillage tool.

6. Depth control cylinders

not working properly.

A. Depth control cylinders out

of phase.

Rephase cylinders by fully extend-

ing and holding tractor remote

lever for 30 seconds.

B. Hydraulic hoses not con-

nected properly or faulty

hyd. coupler.

Reconnect hydraulic hoses or

replace hydraulic coupler.

C. Tractor hydraulics not set

properly.

Adjust tractor hydraulic flow rate to

maximum on Depth Control Cir-

cuit.

7. Wing lift cylinders move

too fast.

A. One way restrictor(s) not

installed properly.

Check resistor(s) (PN 8J7116). Ar-

row must point towards cylinder.

B. Tractor hydraulics not set

properly.

Reduce flow rate to Wing Lift Cyl-

inder Circuit.