High Country Tek emc-1V User Manual
Page 13
Part No:-
021-00351 Rev 1.0
emc-1P & emc-1V e-Fan System Controller User Guide
Page 13
e-Fan Cooling System Controllers
with J1939 Interface
Error LED Code Descriptions for emc-1P & emc-1V
Status
Led
Error
LED
Description
Alarm Out
Fan Out
Reverse
operation
Static
off
Normal Operation
off
normal
normal
Flashing
off
Reverse Cycle
off
rev cycle
cycle On
Static
Static
Fire Input on
on
off
off
Static
Static
Thermistor open/short
on
maximum
normal
Static
Flashing Fan Diag. Error
on
retry
normal
Static
Flashing Alarm out short
off
normal
normal
Static
Flashing Reverse out short
on
normal
off
Static
Static
Can message Timeout
on
maximum
normal
Flashing
Flashing Cooling system over‐temp
on
maximum
manual only
Static
Static
Module over temp
on
normal
normal
Note: * Fire input is available on the emc‐1P only.