ORDERING INFORMATION

MODELS WITHOUT SECOND INPUT OPTIONS

HEATER CURRENT MONITOR MODELS (HCM)

SECOND ANALOG INPUT MODELS (ANA)

MOTORIZED VALVE POSITIONER MODELS (MVP)

ACCESSORIES

9

Type 4X/IP65

BEZEL

4 to 20 mA

ANALOG

OUTPUT

0 to 10 VDC

ANALOG

OUTPUT

ALARM

OUTPUTS

COOLING

OUTPUT

RS485 COM

PART NUMBER

115/230 VAC

NO

NO

NO

NO

NO

NO

TCU00000

NO

NO

NO

2

NO

NO

TCU00001

NO

NO

NO

1

YES

NO

TCU00002

NO

YES

NO

2

NO

NO

TCU01001

NO

YES

NO

2

NO

YES

TCU01004

NO

YES

NO

1

YES

YES

TCU01005

YES

NO

NO

NO

NO

NO

TCU10000

YES

NO

NO

2

NO

NO

TCU10001

YES

NO

NO

1

YES

NO

TCU10002

YES

YES

NO

2

NO

NO

TCU11001

YES

YES

NO

1

YES

NO

TCU11002

YES

YES

NO

2

NO

YES

TCU11004

YES

YES

NO

1

YES

YES

TCU11005

YES

NO

YES

2

NO

NO

TCU12001

YES

NO

YES

2

NO

YES

TCU12004

YES

NO

YES

1

YES

YES

TCU12005

These models have dual alarm outputs, or single alarm with cooling outputs, with shared common terminals (Form A

Type). As a result, these outputs should be fitted with the same type of output module. The main output (OP1) may be

fitted with any type of output module.

Type 4X/IP65

BEZEL

4 to 20 mA

ANALOG

OUTPUT

0 to 10 VDC

ANALOG

OUTPUT

ALARM

OUTPUTS

COOLING

OUTPUT

RS485 COM

PART NUMBER

YES

NO

NO

2

NO

YES

TCU10204

YES

YES

NO

2

NO

NO

TCU11208

These models have dual alarm outputs, or single alarm with cooling outputs, with shared

common terminals (Form A Type). As a result, these outputs should be fitted with the same type

of output module. The main output (OP1) may be fitted with any type of output module.

Type 4X/IP65

BEZEL

4 to 20 mA

ANALOG

OUTPUT

0 to 10 VDC

ANALOG

OUTPUT

ALARM

OUTPUTS

COOLING

OUTPUT

RS485 COM

PART NUMBER

YES

NO

NO

2

NO

YES

TCU10104

YES

YES

NO

2

NO

NO

TCU11108

YES

NO

YES

2

NO

NO

TCU12108

These models have dual alarm outputs, or single alarm with cooling outputs, with shared

common terminals (Form A Type). As a result, these outputs should be fitted with the same

type of output module. The main output (OP1) may be fitted with any type of output module.

Type 4X/IP65

BEZEL

4 to 20 mA

ANALOG

OUTPUT

0 to 10 VDC

ANALOG

OUTPUT

ALARM

OUTPUTS

COOLING

OUTPUT

RS485 COM

PART NUMBER

YES

NO

NO

1

NO

YES

TCU10307

YES

YES

NO

1

NO

NO

TCU11306

YES

NO

YES

1

NO

NO

TCU12306

DESCRIPTION

PART NUMBER

Relay Module

OMD00000

Triac Module

OMD00001

Logic/SSR Drive Module

OMD00003

45 A Single Phase Panel Mount SSR

RLY50000

25 A Single Phase DIN Rail Mount SSR

RLY60000

40 A Single Phase DIN Rail Mount SSR

RLY6A000

25 A Three Phase DIN Rail Mount SSR

RLY70000

50:0.1 Ampere Current Transformer

CT005001

40:0.1 Ampere Current Transformer

CT004001

Note: Output Modules are NOT supplied with the controller. When specifying the controller, be

sure to purchase the appropriate output module for the Main Control Output and if necessary,

the alarm output(s), the cooling output, and valve positioner outputs. The controller can be

fitted with any combination of output modules.
The Logic/SSR Drive Module is a switched DC source, intended to drive the DC input of an

SSR power unit. It should never be connected to line voltage.
All output modules are packaged separately and must be installed by the user.