figure 24.

UNDER NO CIRCUMSTANCES SHOULD THE GAS INPUT EXCEED

THE INPUT SHOWN ON THE HEATER MODEL AND RATING

PLATE. OVERFIRING COULD RESULT IN DAMAGE OR SOOTING

OF THE HEATER.

Should it be necessary to adjust the gas pressure to the burners

to obtain the full input rate, the steps below should be followed:

3. Remove the regulator adjustment sealing cap and adjust the pressure

by turning the adjusting screw with a screwdriver. See Figure 24.

Clockwise to increase gas pressure and input rate.

Counterclockwise to decrease gas pressure and input rate.

4. “Clock” the meter as in step 2 above.

5. Repeat steps 3 and 4 until the specified input rate is achieved.

6. Turn the gas control knob to PILOT. Remove the pressure

gauge and replace the sealing cap and the Allen wrench set

screw in the pressure tap opening.