beautypg.com

Installation considerations – State GPG 81 370NEA User Manual

Page 9

background image

9

table 2. heater performance data gpg models

models

storage

capacity

u.s. gallons

input rating btu/hr.

recoVery rate

gph@100°f rise

recoVery rate

gph@140°f rise

maXimum

amperes

120V, 60hz, 10

GPG 81-140

81

140,000

136

97

5

GPG 81-199

81

199,000

193

138

5

GPG 81-270

81

270,000

262

187

5

GPG 81-370

81

370,000

359

256

5

models with letter “A” following the model number have the optional ASme tank construction

.

**The GPG 81-370 is available in natural gas only.

table 3. gas and electrical characteristics

model

Type of Gas

Gas Supply Pressure

Gas manifold Pressure

Volts/Hz

amperes

minimum

maximum

All models

Natural

4.5" W.C. (1.12 kPa)

14" W.C. (3.48 kPa)

3.5" W.C. (0.87 kPa)

120/60

<5

All models

* Propane

4.5" W.C. (1.12 kPa)

14" W.C. (3.48kPa)

3.5" W.C. (0.87 kPa)

120/60

<5

* model GPG 81-370 is not available in Propane