beautypg.com

State GPG 81 370NEA User Manual

Page 31

background image

31

Normally, lime removal will be completed within one hour.

Severe build-up of lime may take longer than an hour to complete

descaling.
Note: To check uN•lIme for continued use, place some scale

or white chalk in a glass with a small amount of uN•lIme. If

the material is vigorously dissolved by the uN•lIme, it can be

reused; if not, the uN•lIme should be replaced.

figure 26.

power burner

keep the area around the burner clear and free of combustible

materials, gasoline or other flammable liquids or vapors.

Do not obstruct burner air openings or ventilation grilles for

combustion air.

typical main burner flame

figure 27.

The main burner flames (Figure 27) should be visually checked

once a year for proper operation. This can be observed through

the observation port on the burner housing. Burner flame should

be blue. DO NOT use the observation port on the side of the tank

to inspect the burner flame.
1. Add a few drops of no. 20 non-detergent oil (GPG 81-140 Thru

81-370) into the oil tubes once every three months.

2. At least annually, contact a qualified service agency for a burner

readjustment, cleaning and other than routine maintenance.

Should the main burner or burner air openings require cleaning,

remove the burner and clean with a soft brush. Clean main

burner orifice with a suitable soft material.

While the water is being run through the tank, insert a

stiff wire, copper tube flattened at one end or an opened

wire coat hanger through the cleanout opening and

scrape out any loose deposits of scale or sediment. This

is an economical way to avoid unnecessary usage of the

deliming solution.
repeat the opening and closing of the cold water inlet valve

as necessary but be sure the heater is completely drained

when ready to introduce the uN•lIme.
upon completion, reinstall the cleanout cover and use a new

cleanout cover gasket (part number 9004099215).
remove the drain valve.

9. Install the long plastic male adapter insert fitting into the drain

valve opening of heater after applying Teflon tape or paste to

threads. Tighten firmly by hand and use wrench or adjustable

pliers to check for secure connection. Do not over tighten to

avoid damage to threads and fittings.

Prepare the up-N-Down Transfer kit
The next step is the preparation on the up-N-Down Transfer kit,

if you have not already done so:
1. With the 5 gallon up-N-Down container in the vertical

position, unscrew the plastic vent cap in the handle and

pierce the plastic membrane over the vent boss under the

cap to allow the container to vent.
note: If your container does not have the vent cap and vent

boss, drill a 3/16” hole in the handle. When you have finished

deliming you will be able to plug this drilled vent with the

stainless steel screw that is supplied with the kit.

2. remove the container’s cap and cut the plastic membrane

located in the 3/4” IPT opening in the cap. Take care to not

damage the threads.

3. Find the 3/4” male adapter, apply teflon tape to the threaded

end and screw it into the 3/4” IPT opening in the cap.

4. Put cap with male adapter back on the container and slide

3/4” hose over end of male adapter and fasten in place using

hose clamp provided.

Delime using Flo-Jug method
5. Slide the hose clamp over end of hose and slide hose over

the male adapter in the water heater drain opening and

secure in place using hose clamp.

6. lift container to the “Pour” Position, see Figure 26, being

careful to keep the vent in the handle above the liquid level

and pour the uN•lIme into the heater.

7. lower container, you may have to place the container on its

empty carton to prevent the uN•lIme from flowing back into

the container.

8. let uN•lIme remain in the heater for 5 minutes and then

lower the container to the “Drain” Position, see Figure 26.

9. Deliming activity is indicated by foaming on the surface of the

uN•lIme. If there is deliming activity, repeat steps 6 thru 8.

This manual is related to the following products: