Maintenance – State GPG 81 370NEA User Manual

Page 28

background image

28

heater where the thermostat senses the drop in water temperature

and activates main burner operation of the water heater.
If the storage tank temperature control is out of calibration, replace

with new control.
SHOulD OVerHeATING OCCur Or THe GAS SuPPly FAIl

TO SHuT OFF, TurN OFF THe mANuAl GAS CONTrOl VAlVe

TO THe Water heater.

temperature-pressure relief ValVe test

Burn hazard.

Hot water discharge.

keep clear of Temperature-

Pressure Relief Valve

discharge outlet.

It is recommended that the Temperature-Pressure relief Valve should

be checked to ensure that it is in operating condition every 6 months.
When checking the Temperature-Pressure relief Valve operation,

make sure that (1) no one is in front of or around outlet of Temperature-

Pressure relief Valve discharge line, and (2) that water discharge

will not cause any property damage, as water may be extremely hot.

use care when operating valve as valve may be hot.
To check the pressure relief valve, lift lever at the end of valve several

times, see Figure 24. The valve should seat properly and operate freely.
If after manually operating the valve, it fails to completely reset and

continues to release water, immediately close the cold water inlet to

the water heater and drain the water heater, see Draining And Flushing

on page 32. replace the Temperature-Pressure relief
Valve with a properly rated/sized new one, see Temperature-Pressure

relief Valve on pages 12-13 for instructions on replacement.

figure 24.

If the Temperature-Pressure relief Valve on water heater weeps

or discharges periodically, this may be due to thermal expansion.
NOTe: excessive water pressure is the most common cause of

Temperature-Pressure relief Valve leakage. excessive water system

pressure is most often caused by "thermal expansion" in a "closed

system." See Closed Water Systems and Thermal expansion on

page 12. The Temperature-Pressure relief Valve is not intended for

the constant relief of thermal expansion.
Temperature-Pressure relief Valve leakage due to pressure build

up in a closed system that does not have a thermal expansion

tank installed is not covered under the limited warranty. Thermal

expansion tanks must be installed on all closed water systems.
DO NOT PluG THe TemPerATure-PreSSure relIeF

VAlVe OPeNING. THIS CAN CAuSe PrOPerTy DAmAGe,

SerIOuS INJury Or DeATH.

Venting system and barometric draft control

The heater is equipped with a double acting barometric draft

control. This control assembly is factory adjusted to automatically

regulate the chimney draft imposed on the unit. The damper gate

must pivot freely in the ring guides. See Figure 23.

barometric draft control

figure 23.

examine the venting system every six months for obstructions

and/or deterioration of the vent piping.
remove all soot or other obstructions from chimney which will

retard free draft.

general

Water heater maintenance includes periodic tank flushing and

cleaning, and removal of lime scale. The power burner should be

inspected and adjusted to maintain proper combustion. refer to

Table 9. A periodic inspection of the venting system and barometric

damper should be made. Where used, the water heating system

circulating pump should be oiled per manufacturer's instructions.
Following are the instructions for performing some of the

recommended maintenance. Power burner inspection and

adjustment should be performed by a competent technician.

table 10.

recommended maintenance schedule

for the gpg heater

COmPONeNTS

OPERaTION

INTerNAl

requIreD

Tank

Flushing

monthly

Sediments

Removal

Semi-Annually

lime Scale

Removal

As required

Un»l_ime

Delimer

Relief Valve

Inspect

Semi-Annually

Circulating Pump

and Power

Burner motor(1)

Oiling

quarterly

SAe No. 20

Non-Detergent

motor Oil

Power Burner

and Ignition

Device (2)

Inspection

and Adjustment Semi-Annually

Combustion Test

kit and Test

Specifications

main Burner

Vent System and

Inspect

Semi-Annually

Barometric

Damper

Inspect

Semi-Annually

Draft Gauge

Anode(s)

Inspect

annually

remote storage tank temperature control

Water temperature in remote storage tank (if used) is controlled by the

storage tank temperature control. The sensing element is mounted

in the hot water storage tank, see Water Piping Diagram section.
A change in water temperature in the storage tank lower than the

tank temperature control setting will cause the sensor to activate the

circulating pump. The pump then circulates the water through the

maintenance