high limit switch

The dual bulb controller (fig. 1) contains the high limit (energy cutoff)

sensor. The high limit switch interrupts main burner gas flow should

the water temperature reach 205°F (96°C).
In the event of high limit switch operation, the appliance cannot be

restarted unless the water temperature is reduced by at least 20°F

(11°C) and the high limit reset button on front of limit control (fig.1)

is depressed.
Continued manual resetting of high limit control, preceded by higher

than usual water temperature is evidence of high limit switch operation.

The following is a possible reason for high limit switch operation:
• A malfunction in the thermostatic controls would allow the gas

control valve to remain open causing water temperature to

exceed the thermostat setting. The water temperature would

continue to rise until high limit switch operation.

Contact your dealer or service agent if continued high limit switch

operation occurs.

digital thermostat

figure 1.

electronic ignition control

each heater is equipped with a Honeywell ignition module. The

Direct Spark Ignition Control module controls the ignition

sequence and gas control operation of the water heater.

ignition module

figure 2.

barometric draft control

The heater is equipped with a double acting barometric draft

control. This control assembly is factory adjusted to automatically

regulate the chimney draft imposed on the unit.

barometric draft control

figure 3.

combustion chamber obserVation port

The combustion chamber observation access panel is located

above and to the left of the burner. A plug located under the

panel, see fig. 5, is inserted into the combustion chamber wall.

This plug should not be removed except, in rare cases, when

the combustion chamber requires cleaning or replacement.

figure 4.

uncrating

uncrate the heater by removing the outside mat and top locator.

The shipping pallet must be removed from the unit. It may be

possible to simply unbolt the base from the pallet and, with

the help of 2 or more persons, work the unit off the pallet.

Some units will be too heavy and will require the use of jacks

or lifting equipment to safely remove the pallet and move the

unit into position. Be careful when moving this heater. It will

tip over easily.
The heater is shipped with a burner and draft control. The

burner and draft control are shipped in separate cartons. They

should be installed as received without any alterations.
Discard the shipping crate and packaging cartons in an

appropriate manner.