trap (sometimes called a dirt leg) must be incorporated in
the piping. The sediment trap must be readily accessible.
Install in accordance with the “Gas Piping” section. Refer to
the current edition of the National Fuel Gas Code (ANSI
Z223.1/NFPA 5 4)
.

HOT-WATER

OUTLET

COLD-

WATER

INLET

UNION

TEMPERATURE-
PRESSURE
RELIEF VALVE

DISCHARGE PIPE
(DO NOT CAP
OR PLUG)

6” MAX. AIR GAP
BELOW DISCHARGE
PIPE

METAL
DRAIN
PAN

FLOOR
DRAIN

DRAIN
VALVE

SHUT-OFF VALVE

SOME

COMPONENTS

NOT SHOWN

FOR CLARITY.

SIDE TAP
(OUTLET)

SIDE TAP
(INLET)

Figure 27.

FILLING THE WATER HEATER

Avoid water heater damage.

Fill tank with water before operating.

Property Damage Hazard

CAUTION

Do not insert the power cord into the electrical
receptacle until the heater has been fully installed.

Never use this water heater unless it is completely full
of water. To prevent damage to the tank, the tank must
be fi lled with water. Water must fl ow from the hot-water
faucet before turning “ON” gas to the water heater.

To fi ll the water heater with water:
1. Close the water heater drain valve by turning handle

to the right (clockwise). The drain valve is on the lower
front of water heater (see Figure 27).

2. If the heater is equipped with plumbing side taps and

they are not connected to piping, ensure that the side
taps have been closed with pipe plugs.

3. Open all hot-water faucets served by the water heater

to allow air to escape from the tank and the water
piping. Ensure any shut-off valves between the heater
and the faucets are the open position.

4. Open the cold-water supply valve to the water heater.

Notes:

• The cold-water supply valve must be left open when

the water heater is in use.

• Avoid water leakage when fi lling the tank. Do not

allow the insulation of the water heater to get wet as
water can reduce the effectiveness of the insulation.

5. To ensure complete fi lling of the tank, allow air to exit

by opening nearest hot-water faucet. Allow water to
run until a constant fl ow is obtained. This will let air
out of the water heater and the piping.

6. Check all water piping and connections for leaks.

Repair as needed.

VENTING

Breathing carbon monoxide can cause brain damage or death.

Always read and understand instruction manual.

Install vent system In accordance with codes.
Do not operate water heater if flood damaged.
Install water heater in accordance with the

instruction manual.

Do not operate if soot buildup is present.
Do not obstruct water heater air intake(s) with

insulating blanket.

Do not place chemical vapor emitting products near

water heater.

Gas and carbon monoxide detectors are available.
Never operate the heater unless it is vented to the

outdoors and has adequate air supply to avoid risks
of improper operation, fire, explosion or asphyxia-
tion.

Analyze the entire vent system to make sure that

condensate will not become trapped in a section of
vent pipe and therefore reduce the open cross
sectional area of the vent.

Breathing Hazard - Carbon Monoxide Gas

WARNING

Important: DO NOT common vent this water heater with
any power vented appliance. DO NOT vent into a common
chimney.