Press ENTER to move to P4.3 from P4.2,
the default manual input temperature
will flash on the LCD.
Press UP to select the flashing value
from 0~9.( Fig. Y)
Press DOWN to select the digit.
Adjustable range is from 0.0~50.0 C
(32.0~122.0 F). The default is 25.0 C
(77.0 F).
Press ENTER to confirm the last
input and return to P4.0.
When you disable the ATC and select
manual temperature compensation,
you need to manually enter the temp.
value of solution into the meter. You
can select any temperature between
0 and 50 C (32 to 212 F). The default
is 25 C (77 F).
o
C
Fig Y
f)P5.0: CELL setting: (CEL)
P5.1: Cell Constant:(SEL)
.
29
P4.3: Manual temp. Compensation:(Int)
The cell constant, K, 1.0, 10,
or 0.1.
U
se Cell Constant 1.0 for
midrange measurements.
U
se Cell Constant 10 for high
range measurements (above 20 mS
or 10 ppt)
U
se Cell Constant 0.1 for low
range measurements (below 20
S
or 10 ppm)
Using the correct cell constant is
important
to obtain the optimal reading
in various
ranges of measurement.
Refer to following
table ranges.
- 840001 Anemometer CFM Datalogger (12 pages)
- 840002 Anemometer Hotwire CFM Datalogger (12 pages)
- 840034 Psychrometer - Anemometer (24 pages)
- 850021 Anemometer RH Pen (8 pages)
- 850022 Anemometer RH Barometer Pen (8 pages)
- 850023 Anemometer SD Card Logger (32 pages)
- 850024 Hot Wire Anemometer SD Card Logger (32 pages)
- 850025 Mini Environmental Quality Meter (16 pages)
- 850026 Mini Environmental Quality Meter (20 pages)
- 850027 Mini Environmental Quality Meter (28 pages)
- 850072 Anemometer Probe (4 pages)
- 850073 Anemometer Probe - Mini Extension (4 pages)
- LUCL-2006 Chlorine Meter (16 pages)
- 850034K AquaShock® Water Purity Kit (24 pages)
- 850036 Large Display Salinity Pen (56 pages)
- 850039 Conductivity TDS Meter - Datalogging (12 pages)
- 850081 Water Quality Meter (12 pages)
- 850082 ATC Temperature Probe (4 pages)
- 850083 Conductivity Probe (4 pages)
- 850084 Conductivity TDS Probe (4 pages)
- 860032 Conductivity - TDS - Salinity Bench-Top Meter (72 pages)
- 850045 Dissolved Oxygen - DO Pen (16 pages)
- 850046K AquaShock DO Kit (28 pages)
- 850087 Dissolved Oxygen Probe 4 Meter Cable (4 pages)
- 850068 Hybrid Powered Environmental Meter (28 pages)
- 850069 Environmental Quality Meter w/Sound (32 pages)
- 850070 Environmental Quality Meter - Mini (8 pages)
- 850071 Environmental Quality Meter (36 pages)
- 800036 WBGT Heat Stress Meter (14 pages)
- 800037 WBGT Heat Stress SD Card Logger (36 pages)
- 800046 Indoor Air Quality Meter (20 pages)
- 800047 Oxygen Pen (16 pages)
- 840052 Data Acquisition Software (26 pages)
- 840051 Datalogger (8 pages)
- 850080 Intelligent Software (12 pages)
- 330001 Laser Pointer - Golden (2 pages)
- 100000 Micro Recording Card (2 pages)
- 330004 Microscope Pen (2 pages)
- 840073 Multimeter - Auto-Ranging (32 pages)
- 840079 Multimeter with True RMS (4 pages)
- 330005 Ultra Violet UV Light Pen (2 pages)
- 100005 Ultrasonic Cleaner - Mini (2 pages)
- 330006 UV Light - Laser Pointer - LED Pen (2 pages)
- 840064 Vacuum Meter (8 pages)