Patch 86231-10 For Rapier Switches and AR800 Series Modular Switching Routers
5
Patch 86231-10 for Software Release 2.3.1
C613-10328-00 REV J
If a DVMRP interface was deleted and then added again, DVMRP routes 
associated with this interface were not reactivated. This issue has been 
resolved.
A fatal error occurred when OSPF was under high load. This issue has been 
resolved.
When deleting a list associated with a policy, all rules were being deleted. 
Now only the rules associated with the policy and list are deleted.
The DELETE SWITCH FILTER command did not work properly when the 
ENTRY parameter was assigned a range with hyphen (“-”). This issue has 
been resolved.
The firewall doubled the IPSPOOF event timeout from 2 minutes to 4 
minutes. This issue has been resolved.
Broadcast TCP packets were being processed by the device, causing fatal 
errors when firewall SMTP Proxy was configured. Non-unicast TCP packets 
are now dropped by IP.
The Designated Router (DR) of the PIM interface was not resetting when the 
RESET PIM INTERFACE command was executed. This issue has been 
resolved.
Packets processed by the firewall were not having their TTL decremented. 
This issue has been resolved.
The PIM Designated Router (DR) is now elected over an entire VLAN 
interface, rather than on a per-port basis.
After VRRP was enabled, the link status of the switch ports was shown as 
UP, even if there was no connection to the ports. This issue has been 
resolved.
“AT-A42” was being incorrectly displayed as “AT-A42X-00” in the output 
of the SHOW SYSTEM command. This issue has been resolved.
PCR: 03217
Module: DVMRP
Level: 2
PCR: 03240
Module: OSPF
Level: 2
PCR: 03241
Module: FIREWALL
Level: 2
PCR: 03250
Module: SWI
Level: 4
PCR: 03255
Module: FIREWALL
Level: 3
PCR: 03296
Module: IPG
Level: 2
PCR: 03297
Module: PIM
Level: 2
PCR: 03301
Module: IPG
Level: 3
PCR: 03303
Module: PIM
Level: 3
PCR: 03333
Module: IPG
Level: 3
PCR: 03336
Module: CORE
Level: 4