SECTION III

ALIGNMENT / ZEROING

2.15 ZEROING ON A 25-METER RANGE

2.15.1 Clip-On

.

WARNING

..

Activating ZOOM 2X when the CNVD-T is used in-

line with other optical sights may induce an error in

the aiming function of those devices.

When being used in-line with an optical sight, the CNVD-T

should be placed in ZOOM 1X, the reticle should be turned

off, and zeroing procedures associated with the primary sight

should be used. Placing the CNVD-T in front of an already

zeroed optic / weapon combination does not necessitate

rezeroing.

2.15.2 Stand-Alone

. Each click of the CNVD-T reticle

moves the shot group about 2.8cm at 25m (when in ZOOM

1X). Other click equivalents are provided in Table 2-1.

Changing the position of the reticle corresponds to a

subsequent change in shot group movement (i.e., the

UP

button will move the strike of the round up).

Table 2-1 Reticle Adjustments

Single Click Equivalents

10m

25m

100m

150m

300m

ZOOM 1X

1.1cm

2.8cm

11.0cm 16.5cm 33.0cm

ZOOM 2X

0.6cm

1.4cm

5.5cm

8.3cm

16.5cm