2.15 ZEROING ON A 25-METER RANGE
2.15.1 Clip-On
.
WARNING
..
Activating ZOOM 2X when the CNVD-T is used in-
line with other optical sights may induce an error in
the aiming function of those devices.
When being used in-line with an optical sight, the CNVD-T
should be placed in ZOOM 1X, the reticle should be turned
off, and zeroing procedures associated with the primary sight
should be used. Placing the CNVD-T in front of an already
zeroed optic / weapon combination does not necessitate
rezeroing.
2.15.2 Stand-Alone
. Each click of the CNVD-T reticle
moves the shot group about 2.8cm at 25m (when in ZOOM
1X). Other click equivalents are provided in Table 2-1.
Changing the position of the reticle corresponds to a
subsequent change in shot group movement (i.e., the
UP
button will move the strike of the round up).
Table 2-1 Reticle Adjustments
Single Click Equivalents
10m
25m
100m
150m
300m
ZOOM 1X
1.1cm
2.8cm
11.0cm 16.5cm 33.0cm
ZOOM 2X
0.6cm
1.4cm
5.5cm
8.3cm