ADTRAN ATLAS 800PLUS User Manual
Page 106
Chapter 6. Creating a Dedicated Map
6-2
ATLAS 800
PLUS
User Manual
61200226L1-1
Configure the Ports
1.
From the Terminal menu, navigate to the Module menu and select Controller T1/
PRI port (slot 0). Select Menu [+], then the Configuration submenu, then set the
line framing parameters. Once properly configured to match the framing
parameters of the T1 line being provided by the Telco, copy the configuration
information by navigating to the first column (port index number) of this port
and pressing
C
. (See Figure 6-2.)
Figure 6-2. Slot 0 Module Configuration Menu
Table 6-1. Connections
Name
ATLAS 800
PLUS
DS0s
Name
ATLAS 800
PLUS
Port
DS0s
T1-A
Data
Controller T1
Slot 0 Port 1
9-24
RBS Off
V.35 - A
Quad V.35
Slot 2/Port 1
N/A
T1-B
Data
Controller T1
Slot 0/Port 2
9-24
RBS Off
V.35 - B
Quad V.35
Slot 2/Port 2
N/A
T1-C
Data
Quad T1/PRI
Slot 1/Port 1
9-24
RBS Off
V.35 - C
Quad V.35
Slot 2/Port 3
N/A
T1-A
Voice
Controller T1
Slot 0/Port 1
1-8
RBS On
T1-D
Quad T1/PRI
DSX
Slot 1/Port 2
1-8
RBS On
T1-B
Voice
Controller T1
Slot 0/Port 2
1-8
RBS On
T1-D
Quad T1/PRI
DSX
Slot 1/Port 2
9-16
RBS On
T1-C
Voice
Quad T1/PRI
Slot 1/Port 1
1-8
RBS On
T1-D
Quad/PRI DSX
Slot 1/Port 2
17-24
RBS On