DUCT FITTINGS
This Hood Must Use an 8”
Round Duct. It Can Transition
WRDµ[µ'XFW
Use this chart to compute
PD[LPXPSHUPLVVLEOHOHQJWKVIRU
duct runs to outdoors.
NOTE:'RQRWH[FHHGPD[LPXP
permissible equivalent lengths!
Maximum duct length:
100 feet.
Flexible ducting:
,IIOH[LEOHPHWDOGXFWLQJLVXVHG
all the equivalent feet values
in the table should be doubled.
7KHIOH[LEOHPHWDOGXFWVKRXOG
be straight and smooth and
H[WHQGHGDVPXFKDVSRVVLEOH
'2127XVHIOH[LEOHSODVWLF
ducting.
NOTE: Any home ventilation
system, such as a ventilation
hood, may interrupt the proper
flow of combustion air and
exhaust required by fireplaces,
gas furnaces, gas water heaters
and other naturally vented
systems. To minimize the chance
of interruption of such naturally
vented systems, follow the
heating equipment manufacturer’s
guidelines and safety standards
such as those published by NFPA
and ASHRAE. When applicable,
install any makeup (replacement)
air system in accordance with
local building code requirements.
Visit GEAppliances.com for
available makeup air solutions.
Installation Preparation
* Actual length of straight duct plus
duct fitting equivalent. Equivalent
length of duct pieces are based
on actual tests conducted by GE
Evaluation Engineering and reflect
requirements for good venting
performance with any ventilation
hood.
Total
Equivalent
Quantity
Equivalent
Duct Piece
Dimensions
Length*
Used
Length
8” Round,
1 ft.
straight
(per
foot
length)
µ[µ
IW
straight
(per
foot
length)
8” 90° elbow
17
ft.
8” 45° elbow
10
ft.
øµ[µ
90° elbow
43 ft.
µ[µ
45° elbow
26 ft.
µ[µ
90° flat elbow
102 ft.
8” round to
µ[µWUDQVLWLRQ
IW
µ[µWRµ
round transition
5 ft.
8”
round
WRµ[µ
transition 90° elbow
6 ft.
µ[µWRµURXQG
round transition 90° elbow 13 ft.
8”
Round
wall
cap
with damper
32 ft.
µ[µZDOOFDS
with damper
75 ft.
8”
Round
roof cap
44 ft.
Round
roof vent
24 ft.
Total Duct Run