Unit attention sense key – HP NonStop G-Series User Manual
Page 162
![background image](/manuals/398771/162/background.png)
Troubleshooting
Silo Media Manager Installation and User’s Guide — 541559-001
C -22
UNIT ATTENTION SENSE KEY
UNIT ATTENTION SENSE KEY
The library generates a Unit Attention sense key for all initiators if the library
needs to inform the host of an asynchronous event.
INSUFFICIENT RESERVATION RESOURCES
SMM Message: 6291: Sense Data - Unit Attention, Power-On Occurred
Explanation:
The library generates this type of Unit Attention when the library is powered-on,
IPLed from the operator panel, or reset over the SCSI bus. A Unit Attention is
generated for all initiators.
SCSI BUS RESET
SMM Message: 6292: Sense Data - Unit Attention, SCSI Bus Reset
Explanation:
The library generates this type of Unit Attention to all initiators after the SCSI
bus is clear of all I/O processes following a hard reset.
BUS DEVICE RESET MESSAGE OCCURRED
SMM Message: 6292: Sense Data - Unit Attention, Bus Device Reset Message Occurred
Explanation:
The library generates this message to all initiators after the library is clear of
all I/O processes following a hard reset.
NOT READY TO READY TRANSITION
SMM Message: 6280: Sense Data - Unit Attention, Not Ready-to-Ready Transition
Description
Sense
Key
ASC
ASCQ
Power-On Occurred
6h
29h
01h
Not Ready-to-Ready Transition
6h
28h
00h
CAP Element Accessed
6h
28h
01h
Mode Parameters Changed
6h
2Ah
01h
Reservations Preempted
6h
2Ah
03h
Reservations Release
6h
2Ah
04h
Registrations Preempted
6h
2Ah
05h
Microcode Has Been Changed
6h
3Fh
01h
SCSI Bus Reset
6h
29h
02h
Bus Device Reset Message Occurred
6h
29h
03h