HP Storage Essentials Enterprise Edition Software User Manual
Page 70
Operational Details
56
This is an internal check from the Integration core service to ensure that the Managed node is
accessible and configured in the Application Integration Software. If the Managed Node is not
accessible, a potential problem can be that communication between OpenSSH from HP-SIM
server to Managed Node is broken. Check the OpenSSH installation and run the specified
communication checks (see “Installing OpenSSH” on page 32) to ensure communication from
HP Storage Essentials SRM and HP SIM to Managed Node.
Another potential issue can be that the Managed node is indicated as missing in HP Storage
Essentials SRM. This would happen if a Managed node was discovered, but for some reason HP
Storage Essentials SRM could not make contact to this node during the last hardware check
process. In this case, check that the credentials for the Managed node is correct in HP Storage
Essentials SRM and ensure that the CIM extensions service is running on the Managed Node.
8.
Un-mount/Export File system.
The Application Integration Software will now call the active host management module added to
HP SIM to perform the necessary operations on the Managed node to un-mount and export the
file systems associated with this SRID.
For this operation to succeed, the OpenSSH communication with the host must be functional.
For more details on execution errors, check the tasks log in HP SIM.
If some user or process is still accessing a file system, it is possible that the operation will fail. In
this case, ensure that application shutdown was performed correctly, and that all processes
using this file system is stopped.
9.
Un-present physical storage from the Host.
The Integration core uses the HP Storage Essentials SRM API to request a provisioning-action for
the specific storage array in order to remove the presentations for the specific physical storage
from the Managed Node.
Provisioning-errors can occur if the service processor (SVP) of the storage array is in a locked
status. It is important to minimize the use of the SVP for any storage changes, instead, it is
recommended to perform all storage changes using HP Storage Essentials SRM.
For more details on the failure, check the HP Storage Essentials SRM log files and the storage
array audit trails.
10.
Return success/failure.
If all operations are successful, the integration core will return success status to the integration
library and to the sapacosprep module. If any operation fails during the un-mount or un-present
operations, the Integration core will attempt to roll back any changes, leaving the managed
node in the same state that the operation started with, and return “failure” to the integration
library and to the sapacosprep module.
11.
Call platform specific library with “deactivate IP”.
SAP ACC resumes control of operations and calls the platform specific library, using
sapacosprep module, to deactivate the instance virtual IP address.
Any errors during this operation can be due to OpenSSH communication or errors in the
Platform specific library. Monitor the SAP ACC application log for any errors.