Limit value, Limit count, Condition – HP 3PAR System Reporter Software User Manual
Page 124: Condition value, Recipient, Example of an alert rule, Scheduling reports
Limit Value
Specifies the value that the Metric is compared to. This should be a number.
Limit Count
The alert will only be generated if the number of objects for which the Metric exceeds the Limit
Value (in the direction specified by Direction) is greater than Limit Count in any given sample. This
should be an integer.
Condition
Specifies the condition (min_read_iops, min_write_iops, min_total_iops) that should be monitored.
Condition Value
Specifies the condition value.
Recipient
Email address to which the alert email should be sent.
Example of an Alert Rule
shows an example of a configured alert. In this example, System Reporter
will send an email alert to email@address each time it inserts a high-resolution sample in which
more than 0 (Limit Count) VLUNs (including VLUNs in all systems) has a total (reads and writes
included) average service time in millisecs of greater than (>) 1000 (Limit Value).
Figure 47 Example of an alert rule
An example of the email alert is shown
Figure 48 Example of an alert email
The email shows that a single VLUN instance had an average total service time of 2098.800680
millisec during a high-resolution sampling interval.
Scheduling Reports
You can have a predefined report run according to a predetermined schedule by choosing the
Scheduled Reports tab from the System Reporter Policies window (
).
124
Configuring the System Reporter Policy Settings