beautypg.com

HP XP Racks User Manual

Page 62

background image

For XP1024/XP128 Disk Array, RAID Manager supports four types of port names for host groups:

Specifying the port name without a host group:

CL1-A CL1-An where n unit ID for multiple RAID

Specifying the port without a host group:

CL1-A-g where g : host group CL1-An-g where n-g : host group=g on CL1-A in unit ID=n
The following ports can only be specified for XP12000 Disk Array/XP10000 Disk Array and
XP24000/XP20000 Disk Array:

Option

Option

Option

Basic

Port

rn

qn

pn

nn

mn

ln

kn

jn

hn

gn

fn

en

dn

cn

bn

an

CL5

rn

qn

pn

nn

mn

ln

kn

jn

hn

gn

fn

en

dn

cn

bn

an

CL6

rn

qn

pn

nn

mn

ln

kn

jn

hn

gn

fn

en

dn

cn

bn

an

CL7

rn

qn

pn

nn

mn

ln

kn

jn

hn

gn

fn

en

dn

cn

bn

an

CL8

rn

qn

pn

nn

mn

ln

kn

jn

hn

gn

fn

en

dn

cn

bn

an

CL9

rn

qn

pn

nn

mn

ln

kn

jn

hn

gn

fn

en

dn

cn

bn

an

CLA

rn

qn

pn

nn

mn

ln

kn

jn

hn

gn

fn

en

dn

cn

bn

an

CLB

rn

qn

pn

nn

mn

ln

kn

jn

hn

gn

fn

en

dn

cn

bn

an

CLC

rn

qn

pn

nn

mn

ln

kn

jn

hn

gn

fn

en

dn

cn

bn

an

CLD

rn

qn

pn

nn

mn

ln

kn

jn

hn

gn

fn

en

dn

cn

bn

an

CLE

rn

qn

pn

nn

mn

ln

kn

jn

hn

gn

fn

en

dn

cn

bn

an

CLF

rn

qn

pn

nn

mn

ln

kn

jn

hn

gn

fn

en

dn

cn

bn

an

CLG

Target ID: Defines the SCSI/fibre target ID number of the physical volume on the specified
port. See

“Fibre/FCoE-to-SCSI address conversion ” (page 52)

for further information about

fibre address conversion.

LU#: Defines the SCSI/fibre logical unit number (LU#) of the physical volume on the specified
target ID and port.

For fibre channel, if the TID and LU# displayed on the system are different from the TID on the fibre
address conversion table, then use the TID and LU# indicated by the raidscan command in the
RAID Manager configuration file.

MU# for Business Copy/Business Copy/Snapshot: Defines the mirror unit number (0 - 2) if
using redundant mirror for the identical LU on Business Copy. If this number is omitted it is
assumed to be zero (0). The cascaded mirroring of the S-VOL is expressed as virtual volumes
using the mirror descriptors (MU#1-2) in the configuration definition file. The MU#0 of a mirror
descriptor is used for connection of the S-VOL. The mirror descriptor (MU#0-2) can be used
on Business Copy and Business Copy/Snapshot. MU#3-63 can only be used on Business
Copy/Snapshot.

S-VOL

P-VOL

SMPL

Feature

MU#1-63

MU#0

MU#3-63

MU#0-2

MU#3-63

MU#0-2

Invalid

valid

Invalid

valid

Invalid

valid

Business Copy

Valid

valid

valid

valid

valid

valid

Snapshot

62

Sample configuration definition files

This manual is related to the following products: