Lun configurations on the raid storage systems – HP XP Racks User Manual
Page 53
Example 6 Using Raidscan to Display TID and LUN for Fibre-Channel Devices
C:\>raidscan -pd hd6 -x drivescan hd6
Harddisk 6... Port[ 2] PhId[ 4] TId[ 3] Lun[ 5] [HITACHI ] [OPEN-3 ]
Port[CL1-J] Ser#[ 30053] LDEV#[ 14(0x00E)]
HORC = SMPL HOMRCF[MU#0 = SMPL MU#1 = SMPL MU#2 = SMPL]
RAID5[Group 1- 2] SSID = 0x0004
PORT# /ALPA/C,TID#,LU#.Num(LDEV#....)...P/S, Status,Fence,LDEV#,P-Seq#,P-LDEV#
CL1-J / e2/4, 29, 0.1(9).............SMPL ---- ------ ----, ----- ----
CL1-J / e2/4, 29, 1.1(10)............SMPL ---- ------ ----, ----- ----
CL1-J / e2/4, 29, 2.1(11)............SMPL ---- ------ ----, ----- ----
CL1-J / e2/4, 29, 3.1(12)............SMPL ---- ------ ----, ----- ----
CL1-J / e2/4, 29, 4.1(13)............SMPL ---- ------ ----, ----- ----
CL1-J / e2/4, 29, 5.1(14)............SMPL ---- ------ ----, ----- ----
CL1-J / e2/4, 29, 6.1(15)............SMPL ---- ------ ----, ----- ----
Specified device is LDEV# 0014
In this case, the target ID indicated by the raidscan command must be used in the configuration
definition file. This can be accomplished using either of the following two methods:
•
Using default conversion table. Use the TID# and LU# indicated by the raidscan command in
the HORCM configuration definition file (TID=29 LUN=5 in
Display TID and LUN for Fibre-Channel Devices”
).
•
Changing default conversion table. Change the default conversion table using the
HORCMFCTBL environmental variable (see
Example 7 “Using HORCMFCTBL to Change the
Default Fibre Conversion Table”
) (TID=3 LUN=5 in
Example 7 “Using HORCMFCTBL to Change
the Default Fibre Conversion Table”
).
Example 7 Using HORCMFCTBL to Change the Default Fibre Conversion Table
C:\> set HORCMFCTBL=X
→ 'X' is fibre conversion table number.
C:\> horcmstart ...
→ Start of HORCM.
:
:
Result of "set HORCMFCTBL=X" command:
C:\>raidscan -pd hd6 -x drivescan hd6
Harddisk 6... Port[ 2] PhId[ 4] TId[ 3] Lun[ 5] [HITACHI ] [OPEN-3 ]
Port[CL1-J] Ser#[ 30053] LDEV#[ 14(0x00E)]
HORC = SMPL HOMRCF[MU#0 = SMPL MU#1 = SMPL MU#2 = SMPL]
RAID5[Group 1- 2] SSID = 0x0004
PORT# /ALPA/C,TID#,LU#.Num(LDEV#....)...P/S,Status,Fence,LDEV#,P-Seq#,P-LDEV#
CL1-J / e2/0, 3, 0.1(9).............SMPL ---- ------ ----, ----- ----
CL1-J / e2/0, 3, 1.1(10)............SMPL ---- ------ ----, ----- ----
CL1-J / e2/0, 3, 2.1(11)............SMPL ---- ------ ----, ----- ----
CL1-J / e2/0, 3, 3.1(12)............SMPL ---- ------ ----, ----- ----
CL1-J / e2/0, 3, 4.1(13)............SMPL ---- ------ ----, ----- ----
CL1-J / e2/0, 3, 5.1(14)............SMPL ---- ------ ----, ----- ----
CL1-J / e2/0, 3, 6.1(15)............SMPL ---- ------ ----, ----- ----
Specified device is LDEV# 0014
LUN configurations on the RAID storage systems
The RAID storage systems (XP1024/XP128 Disk Array and later) manage the LUN configuration
on a port through the LUN security as shown in the following figure.
LUN configurations on the RAID storage systems
53