beautypg.com

Packageinfo – HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual

Page 9

background image

Commands 9

For VC-Enet Modules

o

VCM Mode: Primary, Backup, Subordinate, Unintegrated

o

Module Configuration: In Sync, Not In Sync, Invalid

o

Domain Configuration (for primary or backup VC-Enet modules): In Sync, Not In Sync

The primary Virtual Connect manager saves the domain configuration data to the backup module in a VC

domain at a regular interval. The 'Domain configuration' state displayed indicates whether this data is in

sync or not between the two modules.
The 'Module configuration' state indicates whether all the modules in an enclosure are in sync with the

primary module with regards to the Virtual Connect configuration information.
If a module is being reconfigured by Virtual Connect, or is rebooting, a 'Not In Sync,' or 'Invalid'
configuration status might be displayed. Wait up to 2 minutes, and then execute the healthcheck
command again.

Item Description

Syntax

vcutil -a healthcheck -i -u -p

Parameters:

IP

IP address of the active OA in the enclosure*

USER

Name of the OA user with privileges to access all enclosure interconnect bays

PWD

Password of the OA user

*In a multi-enclosure environment, this must be the IP address of the active OA in the primary enclosure.

Example
List the state of modules in an enclosure:

vcutil -a healthcheck -i 192.168.0.100 -u Administrator -p password

packageinfo

Extract the package information from the package path supplied and display the following information:

Package Version

Ethernet Firmware Version Timestamp

Ethernet Firmware Supported Hardware

FC Firmware Version

FC Firmware Supported Hardware

Release Notes (extract, not display)

Item Description

Syntax

vcutil -a packageinfo -l

Parameter:

FILE

Full path to the Virtual Connect package on the local computer

Example
Display package information from a file named VCpackage:

vcutil -a packageinfo -l VCpackage