Power supply module voltage sensors, 11 power supply temperature sensors, 12 voltage sensor descriptions – HP MSA Controllers User Manual
Page 64
64
Troubleshooting
When a power supply sensor goes out of range, the Fault/ID LED illuminates amber and an event is
logged to the event log.
Power supply module voltage sensors
Power supply voltage sensors ensure that an enclosure’s power supply voltage is within normal ranges.
There are three voltage sensors per power supply.
Table 11
Power supply temperature sensors
Description
Normal operating range
Power Supply 1 temperature
–10–80°C
Power Supply 2 temperature
–10–80°C
Table 12
Voltage sensor descriptions
Sensor
Event/Fault LED condition
Power supply 1 voltage, 12V
< 11.00V
> 13.00V
Power supply 1 voltage, 5V
< 4.00V
> 6.00V
Power supply 1 voltage, 3.3V
< 3.00V
> 3.80V