beautypg.com

Battery replacement – HP ProLiant DL385 G7 Server User Manual

Page 85

background image

Battery replacement 85

Battery replacement

If the server no longer automatically displays the correct date and time, you may need to replace the

battery that provides power to the real-time clock.

WARNING:

The computer contains an internal lithium manganese dioxide, a vanadium

pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not
properly handled. To reduce the risk of personal injury:

Do not attempt to recharge the battery.

Do not expose the battery to temperatures higher than 60°C (140°F).

Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.

Replace only with the spare designated for this product.

To remove the component:

1.

Power down the server (on page

22

).

2.

Extend the server from the rack (on page

22

).

3.

Remove the access panel (on page

23

).

4.

Remove the full-length expansion board retainer (on page

24

) if any full-length expansion boards are

installed.

5.

Remove the PCI riser cage (on page

25

).

6.

Remove the air baffle (on page

28

).

7.

Remove the battery.

To replace the component, reverse the removal procedure.
For more information about battery replacement or proper disposal, contact an authorized reseller or an