HP 3PAR Policy Manager Software User Manual
Page 33
4.17
Analyzing the Policy Advisor Results for Hardware Changes
3PAR Policy Advisor User’s Guide
The system is checked for active tuning operations:
---------------------------
Active Tune analysis
---------------------------
No active tunes detected on Target InServ
The virtual volumes are analyzed:
--------------------------------------------------------------------
VV USR Space Analysis (VVs in USR space size order, smallest first)
--------------------------------------------------------------------
A total of 1 Virtual Volumes (VVs) will be analyzed
--Rsvd(MB)---(MB)-- ----PDs--- --Chunklets/PD--
ID Name Prov Type Adm Snp Usr Vsize Nodes RAID SetSz Avail CAvail PDType:KRPM Used Avail Max Min Avg
TotalChunks CPG SNP_CPG CreationPattern
3400 aldvv1 full base 0 0 10240 10240 0 1 2 cage port FC:10 16 32 5 5 5.0
80 --- --- -devtype FC
Fields marked with "---" are not applicable
-----------------------------------------
Non-cpg based VVs meeting tuning criteria
-----------------------------------------
Analyzing possible tune commands
A total of 1 Virtual Volumes (VVs) will be analyzed
Name -----Criteria------ ------SkipReason------- ---------TuneCmd----------
aldvv1 {PD usage=16/32 (50%/threshold 90%) of FC:10} tunealdvv -t r1 -ssz 2 -ha
port -p -devtype FC -f aldvv1
After the analysis, the suggested CLI commands you should run are displayed:
---------------------------
Suggested tune command list
---------------------------
tunealdvv -t r1 -ssz 2 -ha port -p -devtype FC -f aldvv1
Total of 1 tune command to run
For a complete list of options available for the
tunealdvv
command, see the InForm OS
Command Line Interface Reference and InForm CLI Help.